KSh 916,670(KSh 1,063,337 Incl VAT)
Device Type: 30kVA / 30kW True Online Double-Conversion Tower UPS (3/3 or 3/1 Configurable)
Model / SKU: NPS-AC30T33I
Brand: Norden
Capacity: 30 kVA / 30 kW (Unity Power Factor, PF = 1.0)
Input: Phase: Three-Phase + Neutral + Earth (3Ph+N+PE); Normal Voltage: 380/400/415 VAC (L-L), 220/230/240 VAC (L-N); Voltage Range: 304–478 VAC (L-L) at Full Load; 304–228 VAC (L-L) with Power Derate from 100% to 50%; Frequency: 50/60 Hz (40–70 Hz); Input Power Factor: >0.99; Current Distortion (THDi): <3% (100% Linear Load)
Output: Output Voltage: 380/400/415 VAC (L-L), 220/230/240 VAC (L-N); Power Factor: 1.0 (Unity); Voltage Regulation: ±1.0%; Frequency Accuracy: 0.1%; Current Crest Ratio: 3:1; Harmonic Distortion (THDv): <1% (Linear Load) / <5% (Non-Linear Load) per IEC 62040-3; Phase Accuracy: 120° ± 0.5°; Waveform: Pure Sine Wave; Output Connection: No sockets — Output Terminal Block
Overload Capability: Normal Mode: 110% for 1 hour; 125% for 10 mins; 150% for 1 min; >150% for 200 ms. Bypass Mode: Same overload ratings
Battery: Battery Type: 12 VDC / 9 Ah VRLA (Valve Regulated Lead Acid); Quantity: 80 PCS (Battery Slots); Charging Capacity: 20% × Pout; Charging Accuracy: ±1%
Bypass: Rated Voltage: 380/400/415 VAC (L-L), 220/230/240 VAC (L-N); Frequency Range: 50/60 Hz (Settable ±1 Hz, ±3 Hz, ±5 Hz); Voltage Range: -40% to +25% (Settable, Default -20% to +15%)
Display & Monitoring: Display: LED + 7-inch Touch LCD; Communication Interface: USB, RS232, RS485, Dry Contact, Air Filter, Cold Start, Internet Port; Optional Features: SNMP Card, Relay Contact Card, Parallel Kit, Air Filter
Alarms & Indicators: Alarm: Two Short (General Alarm — e.g., Main Input Abnormal), One Long (Serious Faults — e.g., Fuse or Hardware Fault), Continuous Alarm (Serious Faults); Indicators: Green (System Working Normally), Red (System Fails or Fault), Yellow (System Warns — Utility Fails, Overload, etc.)
Environmental: Humidity: 0–95% (Non-Condensing); Noise Level: 67–72 dB at Full Load; IP Rating: IP20; Operating Temperature: 0–40°C; Storage Temperature: -25°C to 70°C; Altitude: ≤3000 m Above Sea Level (Derate Power by 2% per 100 m Between 3000 m and 4000 m)
Physical: Dimensions (W×D×H): 350 × 823 × 1200 mm (Approximate for 30kVA Model); Weight: Approx. 262 kg (Standard Model)
Standards & Certifications: Safety: IEC62040-1, IEC60950-1; EMC: IEC62040-2, IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge)
Key Specs: Norden NPS-AC30T33I 30kVA/30kW True Online Double-Conversion Tower UPS, 3/3 or 3/1 Configurable, Unity Power Factor (1.0), Pure Sine Wave Output, Wide Input Range (304–478 VAC L-L), 7-inch Touch LCD, SNMP/USB/RS232/RS485/Dry Contact, 80 × 12V/9Ah Battery Slots (Without Battery), Parallel Kit Optional, IP20, 67–72 dB Noise Level
Usage: Data Centers, Commercial Buildings, Industrial Environments, Mission-Critical IT Infrastructure, Telecommunication Equipment, and Large-Scale Power Backup Applications Requiring Uninterrupted Power