KSh 40,460(KSh 46,934 Incl VAT)
Device Type: 1kVA / 1000W True Online Double-Conversion Tower UPS (Maxion Series)
Model / SKU: NPS-AC01T36IWB
Brand: Norden
Capacity: 1000 VA / 1000 W
Input: Phase: Single Phase with Ground; Normal Voltage: 208/220/230/240 VAC; Input Voltage Range: 110–300 VAC (176–264 VAC @ 100% load; 276–300 VAC @ 50% load); Frequency Range: 50/60 Hz Auto Sensing ±5 Hz; Input Power Factor: ≥0.99 @ Nominal Voltage (100% load); Input Connection: IEC C14
Output: Output Voltage: 208/220/230/240 VAC (Selectable); Output Power Factor: 1.0 (Unity); Voltage Regulation: ±1%; Frequency Range (Battery Mode): 50/60 Hz ±0.1 Hz; Current Crest Ratio: 3:1; Harmonic Distortion (THDv): ≤2% (Linear Load) / ≤5% (Non-Linear Load); Transfer Time: AC to DC: Zero (0 ms) / Inverter to Bypass: 4 ms; Waveform: Pure Sinewave; Output Socket Quantity: 4 × IEC C13
Efficiency: AC Mode: Up to 96%
Battery: Internal Configuration (Standard Model): 3 × 12V/9Ah VRLA (Valve Regulated Lead Acid); System Voltage: 36 VDC; Typical Recharging Time: 4 hours to recover to 90% capacity; Charging Current (Max): 1A (Internal) / 1–12A (Settable, External Battery Configuration); Charging Voltage: 40.5 VDC ±1%; Typical Battery Life: 3–5 Years (Depending on Discharge Cycle)
Display & Alarms: LCD Indicators: Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, and Fault Indicators; Audible Alarms: Battery Mode (Beep every 4 seconds), Battery Low (Beep every second), Overload (Beep twice every second), Fault (Continuous beeping)
Communication & Management: Communication Interface: EPO (Emergency Power Off), RS232, USB, IoT Card, and SNMP Card (Optional); SNMP Support (as specified in product listing)
Protection: Overload, Short Circuit, Voltage Fluctuation; Built-in EMI Filter and Surge Protection; Emergency Power Off (EPO) Function; Cold Start Function
Physical: Form Factor: Tower (Compact); Dimensions (W×D×H): 144 × 355 × 226 mm (Standard Model); Net Weight: Approx. 10.5 kg (Standard Model with Internal Battery); IP Rating: IP20
Environmental: Operating Temperature: 0°C to 40°C; Storage Temperature: -20°C to 70°C; Humidity: 0–95% RH @ 0–40°C (Non-Condensing); Noise Level: <50 dB @ 1 Meter; Altitude: <1000 m
Standards & Certifications: Safety: CE; IEC/EN 62040-1; IEC/EN 62477-1; EMC: IEC/EN 62040-2; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-2-2
Key Specs: Norden NPS-AC01T36IWB Maxion Series 1kVA/1000W True Online Double-Conversion Tower UPS, Unity Power Factor (1.0), Pure Sinewave Output, Zero Transfer Time (AC to DC), 4× IEC C13 Outlets, 96% Efficiency, Wide Input Range (110–300VAC), LCD Display, SNMP/USB/RS232/IoT Optional, EPO Function, Compact Tower Design
Usage: Rack Servers, Network Cabinets, Telecommunication Equipment, Industrial Control Panels, Security & Surveillance Systems, Small Offices, Retail Outlets, and Mission-Critical IT Infrastructure